Minolta Flash meter IV Manual de Instruções

Consulte online ou descarregue Manual de Instruções para Medição, teste e controlo Minolta Flash meter IV. Minolta Flash meter IV Instruction manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - AUTO METER VF

AUTO METER VFInstruction ManualPlease read this manualthoroughly before usingthis product.AutoMeter_VF.qxd 02.7.8 1:31 PM ページ 1

Página 2 - Safety Warnings and Cautions

14 15PreparationsPreparationsSelecting a measuring methodYou can choose between two measuring methods—incident-lightreading and reflected-light readin

Página 3 - Table of Contents

PreparationsPreparations16 17To use a meter for reflected-light measurements, you need to use one ofthe attachments for reflected-light measurements (

Página 4 - Names of Parts and Displays

18 19Thus, incident-light readings are based on this standard value of 18%reflectance. This means that areas of subjects having a reflectance higherth

Página 5 - Data panel displays

20 21In averaging metering, all the reflected light from the entire subject that fitswithin the field of view of the meter is measured using a recepto

Página 6

Basic Operation2322Battery (p. 8)↓Shutter speed increments (p. 12)↓FNo. display (p. 12)↓Film speed (p. 14)↓Incident-light reading andreflected-light

Página 7 - Preparations

Basic OperationBasic Operation24 255Press the measuringbutton to take readings.● The meter will continue to takereadings as long as themeasuring butto

Página 8 - 1. Alt mode

Battery (p. 8)↓CINE (p. 13)↓Film speed (p. 14)↓Incident-light reading andreflected-light reading (p. 15)1Prepare the meter to starttaking readings.Bas

Página 9

Basic Operation2928Basic Operation4Press the display-selectorbutton to set the exposuredisplay units to FNo. orEV.● When the meter is set to displayin

Página 10 - Setting film speed

Basic Operation3130Basic Operation3Attach the flash sync cordto the meter's syncterminal.★ Take care when connectingthe flash to the meter, as th

Página 11 - 2. Reflected-light readings

Basic OperationBasic Operation32 335Press the measuringbutton to take a reading.● The flash light is released andthe meter takes a single readingand d

Página 12 - \Incident-light readings

Thank you for purchasing the MINOLTA AUTO METER VF.The MINOLTA AUTO METER VF offers the following features:● Exposure meter with a built-in microproce

Página 13 - Reflected-light readings

34 35Basic OperationBasic OperationBattery (p. 8)↓Shutter speed increments (p. 12)↓FNo. display (p. 12)↓Film speed (p. 14)↓Incident-light reading andr

Página 14 - Basic Operation

36 37Basic OperationBasic Operation● If the flash does not fire within approx. one minute after the meter goesinto flash waiting mode, or if you press

Página 15 - Display example

Basic Operation38 39Basic OperationWhen making flash light readings, the MINOLTA AUTO METER VF is ableto calculate the proportion of ambient light and

Página 16 - 2. With a cine camera

4140Basic OperationSpecial FunctionsHere we explain how to use the special functions of the MINOLTA AUTOMETER VF.Memory functionUsing the memory butto

Página 17

42 43Special FunctionsSpecial FunctionsS/A/H (Shadow/Average/Highlight)calculationsS/A/H exposure calculation functions cannot be used in AMBI FNo. mo

Página 18 - Measuring flash light

44 45Special FunctionsSpecial FunctionsShadow calculations (for reflected-light readingsonly)When you want to reproduce some detail in the darkest are

Página 19 - Press the measuring

Special Functions4746Special FunctionsHighlight calculations (for reflected-lightreadings only)When you want to reproduce some detail in the brightest

Página 20 - 2. Without a sync cord

48 49Special FunctionsSpecial FunctionsBrightness difference functionPressing the S/A/H button after a normal measurement, or after performingan avera

Página 21

Special Functions50 51Special FunctionsCurrent measurement value(In AMBI mode, measurementsare made continuously while themeasuring button is pressed.

Página 22

Special Functions52 53Special FunctionsFixed averaged valueCurrent measurement value(In AMBI mode, measurementsare made continuously while themeasurin

Página 23 - Special Functions

1Table of ContentsNames of Parts and Displays...2● Data panel displays...

Página 24 - Average exposure

5554Battery (p. 8)↓Battery check (p. 10)↓Film speed (p. 14)2Prepare the meter fortaking a reading.1Attach a Flat Diffuser tothe receptor of theinstrum

Página 25

56 577Press the memory buttonto store the measurementvalue.8Next, position the meterby the subject and take areading with the FlatDiffuser facing the

Página 26

58 59Using as a simplified illuminancemeterAttach the Flat Diffuser (optional accessory), to the meter. Take a readingof ambient light in AMBI mode by

Página 27 - <Display example>

6160Special FunctionsAccessoriesFlat DiffuserWith this diffuser attached, theAUTO METER VF can be used tomeasure lighting contrast (ratio ofbrightness

Página 28 - Measuring brightness

Accessories62 63Care and Storage1. Care1) If the meter gets dirty, it can be wiped with a soft, dry cloth. Do not usesolvents such as thinners or ben

Página 29

64 65Handling InstructionsAfter Service1) Parts for repair of this product shall be available for at least seven yearsfrom the time of purchase.2) For

Página 30 - Flat Diffuser

66 67SpecificationsDisplay range ISO: 3 to 8000 (1/3 stop increments)Shutter speed (ambient): 30 min. to 1/8000 sec. (1, 1/2, 1/3 stop increments)Shut

Página 31

9222-8058-11Minolta Co., Ltd.3-13, 2-Chome, Azuchi-Machi, Chuo-ku, Osaka 541-8556, Japan©2002 Minolta Co., Ltd.ACIAP(1) Printed in JapanAutoMeter_VF.q

Página 32

2 3Names of Parts and DisplaysNames of Parts and DisplaysS/A/H buttonDiffusermounting indexReceptormounting indexAccessory-receptor jack(with cap)Powe

Página 33 - Accessories

2154364 5Names of Parts and DisplaysNames of Parts and DisplaysData panel displaysFor the purpose of explanation, the diagram below shows all indicato

Página 34 - Care and Storage

6 7Names of Parts and DisplaysNames of Parts and Displays9. Measuring mode indicatorsPress the mode button repeatedly to select and display one of the

Página 35 - Handling Instructions

BatteryThe instrument uses a singleAA dry cell.● Manganese dry cell (R-6)● Alkaline-manganese dry cell(LR-6)● Nickel-cadmium rechargeablebattery● Lith

Página 36 - Specifications

The instrument automaticallychecks the battery when power ison.After a new battery is installed, thedisplay appears as shown belowafter the power is t

Página 37 - Minolta Co., Ltd

PreparationsPreparations12 134) TIME/CINE settingSwitches between shutter speed and frame rate in AMBI modeNote that it is not possible to switch to a

Comentários a estes Manuais

Sem comentários